2008 SCION xB MAF TUBE INSTALLATION
Procedure
Issue A: 04/28/08 Page 40 of 48
(f) Install the factory MAF sensor onto the TRD
MAF tube, with the provided 4mm screws. (Fig.
19-4)
Make sure the MAF sensor O-ring is not
pinched and is fully seated inside the MAF
sensor mount on the tube.
(g) Install the aluminum MAF tube between the
rubber inlet tube and the s/c inlet elbow. Secure
using the supplied rubber isolator spacer, 6mm
hardware and the provided hose clamps. USE
HAND TOOLS ONLY. (Fig. 19-5)
(
h) Split the factory MAF harness to gain the
necessary length for the MAF plug to reach the
relocated MAF element. Wrap wire section
with electrical tape.
(i) Reconnect the MAF sensor connector. Torque
to 80 in-lbs. (Fig. 19-5)